Configure EMS applications on TOTVS Fluig Platform

In order to execute EMS programs, it is necessary to configure the Adapter and the Application.

 

 

Registering the Adapter

First, it is necessary to register an adapter that uses the file emshradapter.jar. For such, it is necessary to add a new adapter and on the JAR File inform:  

{$WDKPROTOCOL}://{$WDKHOST}:{$WDKPORT}/{$WDKWEBHOME}/utils/emshradapter.jar

 

The Adapter functionality is available in the Control Panel menu, Documents tab.

 

Registering the application

After registering the adapter, it is necessary to create the application that will execute the EMS.

Click on add and enter the application code and description, select the adapter from the EMS and, in the command line field, insert: 

 

{$PARAM_path_PROGRESS}\bin\prowin32.exe -pf {$PARAM_pf} -basekey ini -ininame {$PARAM_ininame} -p men\men906za.p

 

 

Note

Icon

For unified banks, a new alias file must be created, where the RUN command will be changed, informing the value men/men906za.p.

And on the application command line, the parameter –p must be informed with the path to the new alias file. Example:

{$PARAM_path_PROGRESS}\bin\prowin32.exe –pf {$PARAM_pf} -basekey ini -ininame {$PARAM_ininame} –p f:\datasul\ems\alias.p

It is also necessary to add seven parameters in the Parameters table in the application registration. To include a parameter, just click on Add.

Registered parameters must be configured according to the following table:

Parameter

Value

Variable per User

Password Format

company

1 (EMS Company, usually 1)

No

No

ininame

Inform the INI file path used in the EMS shortcut. Ex: \\servidor\ems\scripts\progress.ini

Optional. If the path is the same for all users, there is no need to be variable.

No

password

Inform the user password in EMS

Yes

Yes

path_PROGRESS

Inform the installation directory path for Progress® on the user’s machine. Example: C:\dlc101b

Yes

No

pf

Inform the PF file path used in the EMS shortcut. Ex: \\servidor\ems\scripts\ems.pf

Optional. If the path is the same for all users, there is no need to be variable.

No

product

Inform the product that will be executed (EMS2, EMS5 or HR). For EMS2.04, use EMS2.

No

No

user

Inform the access user to EMS

Yes

No

Note

Icon

The parameters must be with the coed exactly as shown in column Table parameter above, respecting capitalization.

To ensure that the command line is correctly configured, a simple test can be made in Windows® Execute. Substitute the parameters in the command line for the real values and execute it.

For example, change

From:
{$PARAM_path_PROGRESS}\bin\prowin32.exe -pf {$PARAM_pf} -basekey ini -ininame {$PARAM_ininame} -p men\men906za.p
To:
c:\dlc101b\bin\prowin32.exe -pf f:\ems\scripts\ems.pf  -basekey ini -ininame f:\ems\scripts\progress.ini -p men\men906za.p

 

Publishing an Application

In order to configure a program in EMS, it is necessary to publish a new application under a folder.

 

The EMS application previously configured must be selected, and in the Parameter field, the constant “Program:” must be informed, plus the EMS program path that will be executed. Example:

 

Program:btb/btb001aa.w

 

 Publishing the application, a link will be created on the selected folder. When clicking on the link, the program informed in the application parameters will be open.

 

Configuring the variable parameters

 