Pesquisar

Help

Página 1 de 9. A exibir 90 resultados (0.086 segundos)

  1. TUNSLL_DT_PONTO_DE_ENTRADA_AT190GRV

    At190Grv Manipula os registros a serem gravados na tabela SND (Responsáveis pelos Bens) Características do Requisito Linha de Produto: Microsiga Protheus … Chamados Relacionados TUNSLL País(es): Todos Banco(s) de Dados: Todos homologados para o Protheus. Tabelas Utilizadas: SND Responsáveis pelos Bens Sistema(s
    Linha Microsiga Protheus09 mai, 2016
  2. DBAccess - Messages of DBConsole.log

    <rcvdata> / SND <snddata> ) When a connection with DBAccess is elegantly closed, the message above is displayed, indicating which <thread> was closed, the … <snddata> (Data sent by DBAccess). Exit TopClient Thread (<thread>) TERMINATED (IOs <nnnios> / RCV <rcvdata> / SND <snddata> ) Similar to the message "End
    TOTVS Technology19 abr, 2017
  3. DBAccess - Mensagens do DBConsole.log

    > / RCV <rcvdata> / SND <snddata> ) Quando uma conexão com o DBAccess é encerrada, de forma elegante, é mostrada a mensagem acima, indicando qual a <thread … pelo DBAccess) e <snddata> (Dados enviados pelo DBAccess). Exit TopClient Thread (<thread>) TERMINATED (IOs <nnnios> / RCV <rcvdata> / SND <snddata> ) Similar à
    Tecnologia22 set, 2016
  4. error_indregua.txt

    RCV 373643 SND 1017726 TCBuild 2016101620170331 CREATE INDEX TMPA15170221 ON TMPSC01731015170221(B6DOC,B6SERIE,RECNO,DELET) on INDREGUA(MSLIB.PRW) 11/08/2017
  5. TUBIQ9_DT_Verificação_do_Vínculo_Responsável_SND

    Verificação do Vínculo Responsável SND Linha de Produto: Microsiga Protheus® Segmento: Serviços Módulo: SIGAATF Ativo Fixo Função: AF012AltEx() Verifica … (tabela SND), o sistema permitia a exclusão desse bem sem validar a amarração existente. Solução/Implementação: Foi realizado um ajuste na rotina de cadastro
    Linha Microsiga Protheus11 mai, 2016
  6. Correction - Alter Table with Informix

    SND 1055 TCBuild 20110117 UPDATE informix.TESTE SET CPOCHR = nvl( substr(CPOCHR,1,40)) , ' ' ) ,CPONUM = cast(round( TMPC3,0) as varchar(15)),CPODTA … ) Started 30/08/2012 16:07:53 LastIO IP 172.16.84.64 RCV 2102 SND 1055 TCBuild 20110117 Correction We corrected the statement used for table changes. Additional
    TOTVS Technology09 mai, 2017
  7. _P12.16_MATA340__ERRO NO ENCERRAMENTO DE UM INVENTARIO VIA INTEGRAÇÃO 'M.U.' -“Invalid operation with active transaction”

    ) Started 06/07/2017 14:57:33 LastIO 06/07/2017 15:00:21 IP 192.168.0.51:1700 RCV 42481 SND 110298 TCBuild 2016101620170331 THREAD ERROR (13172, JOBWS01021, THIS) 06 … /2017 15:00:21 IP 192.168.0.51:1700 RCV 42481 SND 110298 TCBuild 2016101620170331 on A340CRITMP(MATA340.PRX) 06/03/2017 16:29:02 line : 2938 TOTVS build
    Linha Microsiga Protheus03 ago, 2017
  8. PSIGAERRO0060 - GPEM009 - Sintaxe incorreta próxima a ')'.on __EXECSQL(APLIB300.PRW) 17/04/2007 17:30:26 line : 46"

    InTran No DBEnv MSSQL/P11sql DBThread (SPID: 51) Started 25/05/2015 10:29:14 LastIO IP 127.0.0.1:1234 RCV 10217163 SND 20647558 TCBuild 20131204 SELECT
    Linha Microsiga Protheus18 set, 2017
  9. TUNSLL_DT_PONTO_ENTRADA_AT190GRV

    Manipula os registros a serem gravados na tabela SND(Responsáveis pelos Bens) Linha de Produto: Microsiga Protheus Segmento: Serviços Módulo: SIGAATF Ativo … alterar o conteudo de algum campo a ser gravado na tabela SND. TUNSLLDTPONTODEENTRADAAT190GRV Chamados relacionados: TUNSLL documentotecnico releasenotes tunsll
    Linha Microsiga Protheus06 mai, 2016
  10. TUBIQ9_DT_VERIFICA_VINCULO_RESPONSAVEL_SND_OLD

    ou exclusão se ele estiver bloqueado. Situação/Requisito: Após incluir um bem e realizar seu vinculo a um responsável (tabela SND) o sistema está permitindo … com "amarração de responsável", e posteriormente excluir o bem juntamente com a amarração, o responsável seja excluído da mesma forma (Tabela SND). Chamados relacionados
    Linha Microsiga Protheus27 jan, 2016